Key features

Smallest conductivity logger on the market
Flexible mounting with protective housing
Different ranges, high or low conductivity
High pressure tolerance
On/off saltwater switch for saving memory

Flexible mounting with protective housing

A plastic protective housing is available, recommended when fastening the data logger to subsea gear and moorings.

Application

The DST CT self contained conductivity measuring device is used for a variety of studies including:

Oceanography and hydrography for long term stationary monitoring in coastal waters
Water quality monitoring with the low conductivity meter

High pressure tolerence

The conductivity recorder can be used in underwater environments from shallow water to deep sea.

Specifications

Sensors Conductivity (salinity) and temperature
Size (Diameter x Length) 15mm x 50mm
Housing Material Alumina (Ceramic)
Weight (in Air/in Water) 21g/13g
Data Resolution 12 bits
Conductivity Ranges Choose between: 13-63 mS/cm, 13-50 mS/cm, 3-37 mS/cm or 0.3 to 5 mS/cm
Conductivity Resolution Range 13-63 mS/cm: 0.02 mS/cm, Range 13-50 mS/cm: 0.01 mS/cm, Range 3-37 mS/cm: 0.01 mS/cm, Range 0.3-5 mS/cm: 0.002 mS/cm
Conductivity Accuracy Range 13-63 mS/cm: +/-2 mS/cm, Range 13-50 mS/cm: +/-1.5 mS/cm, Range 3-37 mS/cm: +/-1.5 mS/cm, Range 0.3-5 mS/cm: +/-0.3 mS/cm
Salinity Range Depends on conductivity and temp. range (consult with Star-Oddi)
Salinity Resolution *Range 13-63 mS/cm: 0.01 PSU, Range 13-50 mS/cm: 0.01 PSU, Range 3-37 mS/cm: 0.01 PSU, Range 0.3-5 mS/cm: 0.0005 PSU
Salinity Accuracy *Range 13-63 mS/cm: +/-1.5 PSU, Range 13-50 mS/cm: +/-1 PSU, Range 3-37 mS/cm: +/-1 PSU, Range 0.3-5 mS/cm: +/-0.1 PSU
Temperature Range -1°C to +40°C (30°F to 104°F)
Temperature Resolution 0.032°C (0.058°F)
Temperature Accuracy +/-0.1°C (0.18°F)
Temperature Response Time Time constant (63%) reached in 20 sec.
Pressure Tolerance 2500m (please provide the depth you are going to use the logger at so the applicable membrane is applied)
Memory Type Non-volatile EEPROM
Memory Capacity 130,826 measurements per sensor
Memory Mangement Custom programming
Sampling Interval User specified in second(s) minute(s), or hour(s)
Minimum Measuring Interval 1 second
Multiple Intervals Option Up to 7 different intervals
Data Retention 25 years
Clock Real time clock. Accuracy +/-1 min/month.
Communications Communication Box, wirelss transmission when DST sits in the box. Connection to PC: USB cable.
Attachment Hole 0.9 mm (diameter)
Battery Life 4 years**
Replaceable Battery No

* Based on conductivity full scale accuracy at 24°C.
** For sampling interval of 10 minutes.
Warranty: 12 months.